VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) Foundation Fieldbus Approval according to LPR radio standard User Manual
Page 69

-
Parabolic antenna
1 g at 5 … 200 Hz according to EN60068-2-6
(vibration with resonance)
Shock resistance
-
Horn antenna
100 g, 6 ms according to EN60068-2-27 (mechan-
ical shock)
-
Parabolic antenna
25 g, 6 ms according to EN60068-2-27 (mechanical
shock)
Data on rinsing air connection
Pressure max.
6 bar (87.02 psig)
Air quantity without reflux valve, with
-
0.2 bar (2.9 psig)
2.0 m
3
/h
-
0.5 bar (7.25 psig)
3.5 m
3
/h
-
1 bar (14.5 psig)
4.5 m
3
/h
-
1.5 bar (21.76 psig)
5 m
3
/h
-
2 bar (29.0 psig)
5.5 m
3
/h
Thread
G⅛ A
Closure, with
-
Non-Ex
Dust protection cover of PE
-
Ex
Threaded plug of 316Ti
Reflux valve - unmounted (as option with non-Ex version, included in the scope of delivery with Ex
version)
-
Material
316Ti
-
Seal
FKM (Viton), FFKM (Kalrez 6375)
-
for tube diameter
6 mm
-
opening pressure
0.5 bar (7.25 psig)
-
Nominal pressure stage
PN
250
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry/plug
6)
-
Single chamber housing
l
1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5
or:
l
1 x closing cap M20 x 1.5; 1 x blind stopper
M
20 x 1.5
or:
l
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5
6)
Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.
VEGAPULS
62 • Approval according to LPR radio standard
69
11 Supplement
41721
-EN
-120301