When using a surge pipe in a vessel, influences from vessel
installations and turbulences can be excluded. Under these prereq-
uisites, the measurement of products with low dielectric values (ε

r

value ≥ 1.6) is possible. In very adhesive products, measurement in a
surge pipe is not recommended.

0%

100%

1

2

3

1

2

3

4

5

8

6

7

9

Fig. 13: Configuration surge pipe

1

Radar sensor

2

Marking of the polarisation plane

3

Thread or flange on the instrument

4

Vent hole

5

Holes

6

Weld joint

7

Welding neck flange

8

Ball valve with complete opening

9

Fastening of the surge pipe

Instructions for orientation:

l

Note marking of the polarisation plane on the sensor

l

With threaded fitting, the marking is on the hexagon, with flange
connection between the two flange holes

l

The marking must show to the direction of the holes in the surge
pipe

Instructions for the measurement:

Measurement in a surge
pipe

VEGAPULS

62 • Approval according to LPR radio standard

19