Vegabar 83, threaded fitting not front-flush, 11 supplement – VEGA VEGABAR 83 4 … 20 mA - Operating Instructions User Manual
Page 69

69
11 Supplement
VEGABAR 83 • 4 … 20 mA
45033-EN-131010
VEGABAR 83, threaded fitting not front-flush
23 mm (0.91"
)
G ½
63 mm (2.48"
)
3 mm (0.12"
)
ø 3 mm
(0.12")
ø 6 mm
(0.24")
½ NPT
¼ NPT
65 mm (2.56"
)
25 mm (0.98"
)
15 mm (0.59"
)
20 mm (0.79"
)
½ NPT
65 mm (2.56"
)
19 mm (0.75"
)
M20x1,5
25 mm (0.98"
) 65 mm (2.56"
)
5 mm (0.20"
)
ø 3 mm
(0.12") ø 6 mm
(0.24")
G½
G¼
60 mm (2.36"
)
17 mm (0.67"
)
20 mm (0.79"
)
3 mm (0.12"
)
ø 17,5 mm
(0.69")
LF
DU
LT
LE
LY
SW 27mm
(1.06")
Fig. 34: VEGABAR 83, threaded fitting not front-flush
DU G½ manometer connection (EN 837)
LT M20 x 1.5 manometer connection (EN 837)
LE G½ A inside G¼ (ISO 228-1)
LF ½ NPT, inside ¼ NPT (ASME B1.20.1)
LY ½ NPT PN 1000
                    See also other documents in the category VEGA Equipment:                                                            
                    - VEGABAR 25 (24 pages)
 - VEGAFLEX 55K (32 pages)
 - VEGABAR 17 (36 pages)
 - D80 Hydrostatic pressure transmitters (40 pages)
 - VEGAMET 513 (52 pages)
 - D81 Hydrostatic pressure transmitter (44 pages)
 - VEGASTAB 690 (12 pages)
 - VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
 - VEGACONNECT 2 (4 pages)
 - D81 METEC Hydrostatic pressure transmitter (44 pages)
 - VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
 - VEGAMET 515 (68 pages)
 - VEGAFLEX 52K (32 pages)
 - Capacitive electrodes EK Profibus PA (56 pages)
 - VEGATOR 631 S1 (4 pages)
 - VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
 - Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
 - VEGABAR 65 4 … 20 mA_HART (76 pages)
 - VEGABAR 64 Profibus PA (80 pages)
 - VEGABAR 44 4 … 20 mA (28 pages)
 - VEGADIS 50 Ex (8 pages)
 - VEGAPULS 51V…54V (96 pages)
 - VEGAFLEX 54P (Profibus PA) (48 pages)
 - VEGASEL 643 (16 pages)
 - VEGAPULS 56K (68 pages)
 - VEGAFLEX 54K (36 pages)
 - VEGABAR 41 HART (44 pages)
 - VEGATOR 537 Ex (16 pages)
 - VEGACAP 82-98 (36 pages)
 - VEGADIS 371 Ex (20 pages)
 - Capacitive electrodes EL Profibus PA (56 pages)
 - VEGAFLEX 52V (36 pages)
 - VEGAFLEX 51K (32 pages)
 - VEGALOG 571 EP (Ex) (32 pages)
 - D84 Hydrostatic pressure transmitter (44 pages)
 - VEGABAR 64 Foundation Fieldbus (80 pages)
 - VEGABAR 61 4 … 20 mA_HART (80 pages)
 - VEGASCAN 850 (92 pages)
 - VEGASON 54P…56P Profibus PA (68 pages)
 - D77 Hydrostatic pressure transmitters (24 pages)
 - VEGATRENN 546 Safety barrier type 146 (8 pages)
 - VEGASON 71 - 1 … 75 - 1 (52 pages)
 - VEGABAR 40 HART (40 pages)
 - Capacitive electrodes EL … (44 pages)
 - VEGABAR 24 (28 pages)
 
