VEGA VEGAPULS 61 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART - two-wire Approval according to LPR radio standard User Manual
Page 74

-
Colour - standard PUR
Blue
-
Colour - Ex-version
Blue
Indicating and adjustment module
Voltage supply and data transmission
through the sensor
Indication
LC display in dot matrix
Measured value indication
-
Number of digits
5
-
Size of digits
W x H = 7 x 13 mm (sensors with software ≥ 4.0.0,
hardware ≥ 2.0.0)
W x H = 5 x 8 mm (sensors with software ≤ 3.99,
hardware < 2.0.0)
Adjustment elements
4 keys
Protection rating
-
unassembled
IP
20
-
mounted into the sensor without cover
IP
40
Materials
-
Housing
ABS
-
Inspection window
Polyester foil
Integrated clock
Date format
Day.Month.Year
Time format
12 h/24 h
Time zone Ex factory
CET
Measurement electronics temerature
Resolution
1 °C (1.8 °F)
Accuracy
±
1 °C (1.8 °F)
Voltage supply
Operating voltage
-
Non-Ex instrument
9.6 … 36 V DC
-
Ex-ia instrument
9.6 … 30 V DC
-
Ex-d-ia instrument
14 … 36 V DC
-
Ex-d-ia instrument with ship approval
15 … 36 V DC
Operating voltage with illuminated indicating and adjustment module
-
Non-Ex instrument
16 … 36 V DC
-
Ex-ia instrument
16 … 30 V DC
-
Ex-d-ia instrument
20 … 36 V DC
Interpolation protection
Available
Permissible residual ripple - Non-Ex, Ex-ia instrument
74
VEGAPULS
61 • Approval according to LPR radio standard
11 Supplement
41713
-EN
-120301