VEGA VEGAPULS 61 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART - two-wire Approval according to LPR radio standard User Manual
Page 73

l
1 x closing cap M20 x 1.5; 1 x blind stopper
M
20 x 1.5
or:
l
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5
-
Double chamber housing
l
1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5; 1 x blind stopper
M
16 x 1.5 or optional
6)
1 x plug M12 x 1 for
external indicating and adjustment unit
or:
l
1 x closing cap ½ NPT, 1 x blind stopper
½
NPT, 1 x blind stopper M16 x 1.5 or
optionally
7)
1 x plug M12 x 1 for external
indicating and adjustment unit
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5; 1 x blind stopper M16 x 1.5
or optionally
8)
1 x plug M12 x 1 for external
indicating and adjustment unit
Spring-loaded terminals for wire cross-section
-
Massive wire, cord
0.2 … 2.5 mm² (AWG 24 … 14)
-
Stranded wire with end sleeve
0.2 … 1.5 mm² (AWG 24 … 16)
Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry
-
Single chamber housing
1 x IP 68 cable gland M20 x 1.5; 1 x blind stopper
M
20 x 1.5
-
Double chamber housing
1 x IP 68 cable gland M20 x 1.5; 1 x blind stopper
M
20 x 1.5; 1 x blind stopper M16 x 1.5
Connection cable
-
Wire cross-section
0.5 mm² (AWG 20)
-
Wire resistance
<
0.036 Ω/m
-
Tensile strength
<
1200 N (270 lbf)
-
Standard length
5 m (16.4 ft)
-
Max. length
180 m (590.6 ft)
-
Min. bending radius
25 mm (0.984 in) with 25 °C (77 °F)
-
Diameter approx.
8 mm (0.315 in)
-
Colour - standard PE
Black
6)
Only with Ex d version
7)
Only with Ex d version
8)
Only with Ex d version
VEGAPULS
61 • Approval according to LPR radio standard
73
11 Supplement
41713
-EN
-120301