VEGA VEGAPULS 61 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART - two-wire Approval according to LPR radio standard User Manual
Page 41
l
Vessel of metal: weld joints
l
Process/measurement conditions:
-
Filling too close to the sensor
-
System noise with completely empty silo increased
-
Automatic false signal suppression with partly filled vessel
Bunker (large-volumed):
l
Vessel of concrete or metal:
-
Structured vessel walls
-
Installations present
l
Process/measurement conditions:
-
Large distance to the medium
-
Large angles of repose
Bunker with fast filling:
l
Vessel of concrete or metal, also multiple chamber silo:
-
Structured vessel walls
-
Installations present
l
Process/measurement conditions:
-
Measured value jumps, e.g. by truck loading
-
Large distance to the medium
-
Large angles of repose
Heap:
l
Sensor mounting on movable conveyor belts
l
Detection of the heap profile
l
Height detection during filling
l
Process/measurement conditions:
-
Measured value jumps, e.g. by the profile of the heap or
traverses
-
Large angles of repose
-
Measurement near the filling stream
Crusher:
l
Vessel: installations, wear and protective facilities available
l
Process/measurement conditions:
-
Measured value jumps, e.g. by truck loading
-
Fast reaction time
-
Large distance to the medium
Demonstration:
l
Adjustment for all applications which are not typically level
measurement
l
Sensor accepts all measured value changes within the measuring
range immediately
l
Typical applications:
-
Instrument demonstration
-
Object recognition/monitoring (additional settings required)
VEGAPULS
61 • Approval according to LPR radio standard
41
6 Set up with the indicating and adjustment module
41713
-EN