Quick start – VEGA VEGAFLEX 83 Modbus and Levelmaster protocol PFA insulated User Manual
Page 2
2
Quick start
VEGAFLEX 83 • Modbus and Levelmaster protocol
41838-EN-130314
Quick start
The quick start procedure enables a quick setup with many applica-
tions. You can find further information in the respective chapters of the
operating instructions manual.
1. Distance from the metallic vessel wall > 300 mm. Distance from
non-metallic vessel wall > 500 mm. The probe must not touch any
installations or the vessel wall.
2. Place a metal sheet beneath the process fitting with non-metal
vessels.
1
2
Fig. 1: Installation in plastic silo
1 Flange
2 Metal sheet
3. If necessary, fasten probe end.
For further information see chapter "Mounting".
1. Make sure that the power supply corresponds to the specifica-
tions on the type label.
2. Connect the instrument according to the following illustration
+
+
power supply
MODBUS
D0
D1
IS GND
USB
1
2
1
3
4
5
2
off on
( )
(
)
(-)
(-)
Fig. 2: Connection compartment
1 USB connection
2 Slide switch for integrated termination resistor (120 Ω)
For further information see chapter "Connecting to power supply".
For standard applications we recommend selecting the "Quick setup"
in the display and adjustment module.
Mounting
Electrical connection
Set parameters