beautypg.com

VEGA VEGAPULS WL 61 Profibus PA User Manual

Page 38

background image

38

9 Supplement

VEGAPULS WL 61 • Profibus PA

38062-EN-121011

Ʋ Reflector

Plane plate reflector

Ʋ False reflections

Largest false echo 20 dB smaller than the useful echo

Deviation with liquids

See following diagrams

0,5 m (1.6 ft)

10 mm (0.394 in)

- 10 mm (- 0.394 in)

2 mm (0.079 in)

- 2 mm (- 0.079 in)

0

1 2

3

Fig. 41: Deviation under reference conditions
1 Reference plane

2 Antenna edge

3 Recommended measuring range

Reproducibility

≤ ±1 mm

Variables influencing measurement accuracy
Temperature drift - Digital output

±3 mm/10 K relating to the max. measuring range or

max. 10 mm

Additional deviation through strong, high

frequency electromagnetic fields acc. to

EN 61326

< ±50 mm

Characteristics and performance data
Measuring frequency

K-band (26 GHz technology)

Measuring cycle time approx.

450 ms

Step response time

1)

≤ 3 s

Tracking speed of the measuring window

max.

1 m/min

Beam angle

2)

10°

Emitted HF power

3)

Ʋ Average spectral transmission power

density

-34 dBm/MHz EIRP

Ʋ Max. spectral transmission power

density

+6 dBm/50 MHz EIRP

Ʋ Max. power density in a distance of

1 m

< 1 µW/cm²

1)

Time span after a sudden distance change of max. 0.5 m until the output signal reaches for the first time 90% of

the final value (IEC 61298-2).

2)

Outside the specified beam angle, the energy of the radar signal has a level which is reduced by 50 % (-3 dB)

3)

EIRP: Equivalent Isotropic Radiated Power