False signal suppression: Deleting a previously created false

signal suppression. The false signal suppression created in the

factory remains active.

Peak values measured value: Resetting of the measured min.

and max. distances to the actual measured value.

Select the requested reset function [->] and confirm with [OK].
The following table shows the default values of VEGAPULS 66:

Menu

Menu item

Default value

Setup

Measurement

loop name

Sensor

Medium

Liquid/Water
Bulk solids/Crushed stones, gravel

Applications

Storage tank
Silo

Vessel form

Vessel bottom, dished boiler end
Vessel top, dished boiler end

Vesell height/

Measuring range

Recommended measuring range, see

"Technical data" in the supplement

Min. adjustment

Recommended measuring range, see

"Technical data" in the supplement

Max. adjustment

0,000 m(d)

AI FB1 Channnel PV (lin. perc.)
AI FB1 scaling

unit

Height
%

AI FB1 scaling

0.00 lin %, 0.00 %
100.00 lin %, 100.00 %

AI FB1 damping

0 s

Lock operation

Released

Display

Language

Like order

Displayed value

SV 1

Backlight

Switched off

Additional adjust-

ments

Distance unit

m

Temperature unit °C
Unit SV2

m

Probe length

Length of the standpipe Ex factory

Linearisation

curve

Linear

Sensor address

126

6.4 Saving the parameter adjustment data

We recommended noting the adjusted data, e.g. in this operating

instructions manual, and archiving them afterwards. They are thus

available for multiple use or service purposes.