beautypg.com

6 wiring plan, external housing with version ip 68 – VEGA VEGABAR 54 Foundation Fieldbus - climate compensated User Manual

Page 22

background image

22

5 Connecting to power supply

VEGABAR 54 • Foundation Fieldbus - climate compensated

36791-EN-130321

5.6 Wiring plan, external housing with version

IP 68

Fig. 15: VEGABAR 54 in IP 68 version 25 bar and axial cable outlet, external

housing

I²C

Display

Typ:

1 2

5 6 7 8

Bus

Sim.

4

5

6

1

2

3

Fig. 16: Electronics and connection compartment, single chamber housing
1 Plug connector for VEGACONNECT (I²C interface)

2 Spring-loaded terminals for connection of the external indication VEGADIS

61

3 Cable gland to the sensor

4 Ground terminal for connection of the cable screen

5 Spring-loaded terminals for Foundation Fieldbus connection

6 Simulation switch ("on" = simulation mode)

Overview

Electronics and connec-

tion compartment