beautypg.com

4 accessories and replacement parts – VEGA VEGAPULS SR 68 Foundation Fieldbus User Manual

Page 12

background image

12

3 Product description

VEGAPULS SR 68 • Foundation Fieldbus

38297-EN-130624

The delivery must be checked for completeness and possible transit

damage immediately at receipt. Ascertained transit damage or con-

cealed defects must be appropriately dealt with.

Up to the time of installation, the packages must be left closed and

stored according to the orientation and storage markings on the

outside.
Unless otherwise indicated, the packages must be stored only under

the following conditions:

Not in the open

Dry and dust free

Not exposed to corrosive media

Protected against solar radiation

Avoiding mechanical shock and vibration

Storage and transport temperature see chapter "Supplement -

Technical data - Ambient conditions"

Relative humidity 20 … 85 %

3.4 Accessories and replacement parts

The display and adjustment module PLICSCOM is used for measured

value indication, adjustment and diagnosis. It can be inserted into the

sensor or the external display and adjustment unit and removed at

any time.
You can find further information in the operating instructions "Display

and adjustment module PLICSCOM" (Document-ID 27835).

The interface adapter VEGACONNECT enables the connection of

communication-capable instruments to the USB interface of a PC. For

parameter adjustment of these instruments, the adjustment software

PACTware with VEGA-DTM is required.
You can find further information in the operating instructions "Interface

adapter VEGACONNECT" (Document-ID 32628).

The VEGADIS 81 is an external display and adjustment unit for VEGA

plics

®

sensors.

For sensors with double chamber housing the interface adapter

"DISADAPT" is also required for VEGADIS 81.
You can find further information in the operating instructions "VE-

GADIS 81" (Document-ID 43814).

The PLICSMOBILE T61 is an external GSM/GPRS radio unit for

transmission of measured values and for remote parameter adjust-

ment of plics

®

sensors. The adjustment is carried out via PACTware/

DTM by using the integrated USB connection.
You can find further information in the supplementary instructions

"PLICSMOBILE T61" (Document-ID 37700).

The protective cover protects the sensor housing against soiling and

intense heat from solar radiation.

Transport inspection

Storage

Storage and transport

temperature

PLICSCOM

VEGACONNECT

VEGADIS 81

PLICSMOBILE T61

Protective cap