VEGA VEGACAP 27 - Relay (DPDT) User Manual
Page 26
26
9 Supplement
VEGACAP 27 • - Relay (DPDT)
33758-EN-130916
Ʋ Single chamber housing
– 1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind plug M20 x 1.5; attached 1 x cable entry
M20 x 1.5
or:
– 1 x cable entry ½ NPT, 1 x blind plug ½ NPT, 1 x cable
entry ½ NPT
or:
– 1 x plug M12 x 1; 1 x blind plug M20 x 1.5
Screw terminals
for wire cross-section up to 1.5 mm² (AWG 16)
Adjustment elements
Mode switch
Ʋ A
Min. detection or dry run protection
Ʋ B
Max. detection or overflow protection
Potentiometer
Switching point adaptation
Voltage supply
Operating voltage
20 … 253 V AC, 50/60 Hz, 20 … 72 V DC (at
U >60 V DC, the ambient temperature can be max.
50 °C/122 °F)
Power consumption
1 … 9 VA (AC), approximately 1.5 W (DC)
Electrical protective measures
Protection rating
IP 66/IP 67
Overvoltage category
III
Protection class
I
Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments have to be carefully
noted. They are part of the delivery or can be do
and "serial number search" as well as via "Downloads" and "Approvals".