VEGA VEGAFLEX 66 (-20…+250°C) Foundation Fieldbus User Manual
Page 51
l
1 x closing cap ½ NPT, 1 x blind stopper
½ NPT
, 1 x blind stopper M16 x 1.5 or
optionally 1 x plug M12 x 1 for VEGADIS 61
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5; 1 x blind stopper M16 x 1.5
or optionally available with 1 x plug M12 x 1 for
VEGADIS
61
Spring-loaded terminals for wire cross-sec-
tion
> 2
.5 mm² (AWG 14)
Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry
-
Single chamber housing
1 x IP 68 cable gland M20 x 1.5; 1 x blind stopper
M
20 x 1.5
-
Double chamber housing
1 x IP 68 cable gland M20 x 1.5; 1 x blind stopper
M
20 x 1.5; 1 x blind stopper M16 x 1.5
Connection cable
-
Wire cross-section
0.5 mm² (AWG 20)
-
Wire resistance
< 0
.036 Ω/m
-
Tensile strength
< 1200 N
(270 lbf)
-
Standard length
5 m (16.4 ft)
-
Max. length
1000 m (3280 ft)
-
Min. bending radius
25 mm (0.984 in) with 25 °C (77 °F)
-
Diameter approx.
8 mm (0.315 in)
-
Colour - standard PE
Black
-
Colour - standard PUR
Blue
-
Colour - Ex-version
Blue
Indicating and adjustment module
Voltage supply and data transmission
through the sensor
Indication
LC display in dot matrix
Adjustment elements
4 keys
Protection rating
-
unassembled
IP
20
-
mounted into the sensor without cover
IP
40
Materials
-
Housing
ABS
-
Inspection window
Polyester foil
VEGAFLEX
66 • Foundation Fieldbus
51
10 Supplement
34172
-
EN
-100426