beautypg.com

4 wiring plan, double chamber housing – VEGA VEGABAR 63 Foundation Fieldbus User Manual

Page 21

background image

I²C

3

4

5

1

2

Display

Typ:

1

2

5 6 7 8

Bus

Sim.

Fig. 9: Electronics and connection compartment, single chamber housing
1

Plug connector for VEGACONNECT (I²C interface)

2

Spring-loaded terminals for connection of the external indication VEGADIS
61

3

Ground terminal for connection of the cable screen

4

Spring-loaded terminals for Foundation Fieldbus connection

5

Simulation switch ("on" = mode for simulation release)

I2C

Display

1

1

2

5

6

7

8

Fig. 10: Wiring plan, single chamber housing
1

Voltage supply/Signal output

5.4 Wiring plan, double chamber housing

The following illustrations apply to the non-Ex as well as to the Ex-ia
version.

Electronics and connec-
tion compartment

Wiring plan

VEGABAR

63 • Foundation Fieldbus

21

5 Connecting to power supply

32464

-

EN

-081209