6 Setup with the integrated display and adjustment unit

PLICSRADIO R61 • Wireless receiving unit (single channel)

32625-EN-130228

6.3 Adjustment system

2

3

1

1.1

Fig. 13: Display and adjustment elements
1 LC display

2 Indication of the menu item number

3 Adjustment keys

[OK] key:

– Move to the menu overview

– Confirm selected menu

– Edit parameter

– Save value

[->] key to select:

– Menu change

– Select list entry

– Select editing position

[+] key:

– Change value of the parameter

[ESC] key:

– interrupt input

– Jump to next higher menu

The sensor is adjusted via the four keys of the display and adjust-

ment module. The LC display indicates the individual menu items. The

functions of the individual keys are shown in the above illustration.

Approx. 10 minutes after the last pressing of a key, an automatic reset

to measured value indication is triggered. Any values not confirmed

with [OK] will not be saved.

6.4 Setup steps

Setup is comprised mainly of the radio connection adjustment (selec-

tion radio channel and safe operation). The selection of the requested

indication value, e.g. in percent, linearized percent or scaled are

further adjustment options (only when using VEGA sensors).

Key functions

Adjustment system

Setup