Nominal range
Overload, max. pressure Overload, min. pressure
G
auge pressure
0 … 0.1
bar/0 … 10 kPa
15
bar/1500 kPa
-0.2
bar/-20 kPa
0 … 0.2
bar/0 … 20 kPa
20
bar/2000 kPa
-0.4
bar/-40 kPa
0 … 0.4
bar/0 … 40 kPa
30
bar/3000 kPa
-0.8
bar/-80 kPa
0 … 1
bar/0 … 100 kPa
35
bar/3500 kPa
-1
bar/-100 kPa
0 … 2.5
bar/0 … 250 kPa
50
bar/5000 kPa
-1
bar/-100 kPa
0 … 5
bar/0 … 500 kPa
65
bar/6500 kPa
-1
bar/-100 kPa
0 … 10
bar/0 … 1000 kPa
90
bar/9000 kPa
-1
bar/-100 kPa
0 … 25
bar/0 … 2500 kPa
130
bar/13000 kPa
-1
bar/-100 kPa
A
bsolute pressure
0 … 1
bar/0 … 100 kPa
35
bar/3500 kPa
0
bar abs.
0 … 2.5
bar/0 … 250 kPa
50
bar/5000 kPa
0
bar abs.
0 … 5
bar/0 … 500 kPa
65
bar/6500 kPa
0
bar abs.
0 … 10
bar/0 … 1000 kPa
90
bar/9000 kPa
0
bar abs.
0 … 25
bar/0 … 2500 kPa
130
bar/13000 kPa
0
bar abs.
Nominal measuring ranges and overload capability in psig
Nominal range
Overload, max. pressure Overload, min. pressure
G
auge pressure
0 … 1.5
psig
200
psig
-3
psig
0 … 3
psig
290
psig
-6
psig
0 … 6
psig
430
psig
-12
psig
0 … 15
psig
500
psig
-15
psig
0 … 35
psig
700
psig
-15
psig
0 … 70
psig
950
psig
-15
psig
0 … 150
psig
1300
psig
-15
psig
0 … 350
psig
1900
psig
-15
psig
0 … 900
psig
2900
psig
-15
psig
A
bsolute pressure
0 … 15
psi
500
psi
0
psi
0 … 35
psi
700
psi
0
psi
0 … 70
psi
900
psi
0
psi
0 … 150
psi
1300
psi
0
psi
0 … 350
psi
1900
psi
0
psi
Output variable
O
utput signal
4 … 20
mA/HART
S
upplement
VEGAWELL
51 • 4 … 20
mA/HART
29
32468
-
EN
-080604