beautypg.com

3 shorten suspension cable – VEGA VEGAWELL 51 4 … 20 mA_HART User Manual

Page 25

background image

à Check the pressure compensation in the housing and

clean the filter element, if necessary

?

4 … 20

mA signal missing

l

W

rong connection to power supply

à Check connection according to chapter "Connection

steps" and if necessary, correct according to chapter
"Wiring plan"

l

N

o voltage supply

à Check cables for breaks; repair if necessary

l

supply voltage too low or load resistance too high

à Check, adapt if necessary

?

C

urrent signal 3.6 mA; 22 mA

l

electronics module or measuring cell defective

à Exchange instrument or return instrument for repair

I

n Ex applications, the regulations for the wiring of intrinsically

safe circuits must be observed.

D

epending on the failure reason and measures taken, the

steps described in chapter "Set up" must be carried out again,
if necessary.

7

.3 Shorten suspension cable

S

horten the suspension cable individually. Proceed as follows:

1

R

emove the filter adapter from the transparent capillary line

2

C

ut the suspension cable with an edge cutter to the

requested length

Caution:
D

o not squeeze the capillary cable, this will influence the

pressure compensation. If necessary, rework with a sharp
knife.

3

R

emove approx. 10 cm of the cable mantle, strip off

approx. 1 cm of the wire ends
I

nsert the filter adapter

T

he work steps are finished.

Reaction after fault rec-
tification

VEGAWELL

51 • 4 … 20

mA/HART

25

M

aintenance and fault rectification

32468

-

EN