9 supplement – VEGA VEGASWING 63 - two-wire User Manual
Page 33
33
9 Supplement
VEGASWING 63 • - two-wire
29232-EN-130409
200 °C
(392 °F)
250 °C
(482 °F)
-50 °C
(-58 °F)
-40 °C
(-40 °F)
0 °C
(32 °F)
40 °C
(104 °F)
70 °C
(158 °F)
50 °C
(122 °F)
100 °C
(212 °F)
150 °C
(302 °F)
1
2
3
Fig. 43: Ambient temperature - Process temperature
1 Process temperature in °C (°F)
2 Ambient temperature in °C (°F)
3 Temperature range with temperature adapter
1
2
-50 °C
(-58 °F)
0 °C
(32 °F)
50 °C
(122 °F)
100 °C
(212 °F)
150 °C
(302 °F)
200 °C
(392 °F)
250 °C
(482 °F)
20
(290)
-1 (-14,5)
40
(580)
64
(928)
Fig. 44: Process temperature - Process pressure with switch position 0.7 g/cm³ (sensitivity switch)
1 Process pressure in bar (psig)
2 Process temperature in °C (°F)
1
2
-50 °C
(-58 °F)
0 °C
(32 °F)
50 °C
(122 °F)
100 °C
(212 °F)
150 °C
(302 °F)
200 °C
(392 °F)
250 °C
(482 °F)
20
(290)
-1 (-14,5)
40
(580)
64
(928)
Fig. 45: Process temperature - Process pressure with switch position 0.5 g/cm³ (sensitivity switch)
1 Process pressure in bar (psig)
2 Process temperature in °C (°F)
Viscosity - dynamic
0.1 … 10000 mPa s (requirement: with density 1)
Flow velocity
max. 6 m/s (with a viscosity of 10000 mPa s)