Ʋ Instrument weight (depending on

process fitting)

approx. 0.8 … 4 kg (0.18 … 8.82 lbs)

Ʋ Tube extension

approx. 920 g/m (9.9 oz/ft)

Layer thickness

Ʋ Enamel

approx. 0.8 mm (0.031 in)

Ʋ ECTFE

approx. 0.5 mm (0.02 in)

Ʋ PFA

approx. 0.5 mm (0.02 in)

Surface quality

Ʋ Standard

R

a

approx. 3 µm (1.18

-4

in)

Ʋ Hygienic version (3A)

R

a

< 0.8 µm (3.15

-5

in)

Ʋ Hygienic version (3A)

R

a

< 0.3 µm (1.18

-5

in)

Process fittings

Ʋ Pipe thread, cylindrical (DIN 3852-A) G¾ A, G1 A

Ʋ American pipe thread, conical

(ASME B1.20.1)

¾ NPT or 1 NPT

Ʋ Flanges

DIN from DN 25, ANSI from 1"

Ʋ hygienic fittings

Bolting DN 40 PN 40, Tri-Clamp 1", Tri-Clamp 1½"

PN 10, conus DN 25 PN 40, Tuchenhagen Varivent

DN 50 PN 10

Max. torque - process fitting

Ʋ Thread G¾ A, ¾ NPT

75 Nm (55 lbf ft)

Ʋ Thread G1 A, 1 NPT

100 Nm (73 lbf ft)

High voltage test (enamel)

max. 5 KV

Output variable
Output

Relay output (DPDT), 2 floating spdts

Turn-on voltage

Ʋ Min.

10 mV

Ʋ Max.

253 V AC, 253 V DC

Switching current

Ʋ Min.

10 µA

Ʋ Max.

3 A AC, 1 A DC

Breaking capacity

Ʋ Min.

50 mW

Ʋ Max.

750 VA AC, 54 W DC
If inductive loads or stronger currents are switched

through, the gold plating on the relay contact surface will

be permanently damaged. The contact is then no longer

suitable for switching low-level signal circuits.

Contact material (relay contacts)

AgNi (Au plated) or AgSnO (Au plated)

Modes (switchable)

Ʋ A

Max. detection or overflow/overfill protection

Ʋ B

Min. detection or dry run protection