VEGABAR 40 (Profibus PA)

7

Product description

Electrical data

Adjustment ranges

Zero

adjustable from -20 … +95 % of nominal range

Span

adjustable from 3.3 … 120 % of nominal range

Supply and signal circuit

Supply voltage

9 … 32 V DC
(delivered by the segment coupler)

Current consumption

10 mA ± 1 mA

Integration time

0 … 50 s

Rise time

85 ms (ti = 0 sec; 0 – 63 %)

Display and adjustment circuit

For connection to

VEGADIS 10 and/or display module

Data transmission

digital

Connection line

4-wire (standard line)

Max. line length

25 m

Connection

Cable entry

M20 x 1.5 (for cable-ø 5 … 10 mm)

Screw terminals

for conductor cross-sections of up to 2.5 mm

2

Recommended bus cable types

- SINEC 6XV 830-5AH10 (Siemens AG)

- SINEC L2 6XV1 830-35H10 (Siemens AG)
- 3079 A (Belden)

Protective measures

Protection

1)

IP 65

Protection class

III

Overvoltage category

III

1)

Use of a suitable seal for the cable in the PG is necessary for maintaining the housing protection. If the seal