beautypg.com

VEGA D98 Pressure transmitter User Manual

Page 5

background image

Pressure transmitter D98

5

Technical data

Influence of the ambient temperature

Average temperature coefficient
of the zero signal

1) 2)

< 0.15 %/10 K

Long-term stability

Long-term stability of the zero signal

1) 3)

< 0.1 %/2 years

Other actuating variables

Vibration resistance

mechanical vibration with 4 g and
5 … 100 Hz, tested acc. to the regulations of
German Lloyd, GL-characteristics 2

Ambient conditions

Temperatures

Ambient temperature

-40°C … +85°C

Storage and transport temperature

-50°C … +85°C

Product temperature

-40°C … +100°C (1 h up to +140°C)

Protective measures

4)

Protection class

IP 66 (EN 60 529)

Connection cable

Cable entry

M20x1.5 (for cable ø 5…9 mm)

Screw terminals

for conductor cross-sections of up to 2.5 mm

2

Materials, wetted parts

Process connection

stainless steel 1.4435

Diaphragm

sapphire-ceramic

®

(99.9 % Oxide-ceramic)

Seal, measuring cell

5)

EPDM

Materials, non-wetted parts

Housing

stainless steel 1.4571

Ground terminal

stainless steel 1.4305

Weight

Weight

1.4 kg … 1.6 kg

CE conformity

The pressure transmitter D98 meets the requirements of EMC (89/336/EC) and NSR (73/23/
EWG). Conformity has been judged according to the following standards:
EMC

emission

EN 50 081 - 1: 1992

susceptibility

EN 50 082 - 2: 1995

NSR

EN 61 010: 1993