VEGA VEGABAR 65 Profibus PA User Manual
Page 58
l
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5
or:
l
2 x blind stopper M20 x 1,5
-
Double chamber housing
l
1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5; plug M12 x 1 for
VEGADIS
61 (optional)
or:
l
1 x closing cap ½ NPT, 1 x blind stopper
½ NPT, plug M12 x 1 for VEGADIS 61
(optional)
or:
l
1 x plug (depending on the version), 1 x blind
stopper M20 x 1.5; plug M12 x 1 for VEGADIS
61 (optional)
or:
l
2 x blind stopper M20 x 1.5; plug M12 x 1 for
VEGADIS
61 (optional)
Spring-loaded terminals for wire cross-sec-
tion
<
2.5 mm² (AWG 14)
Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry
-
Single chamber housing
l
1 x IP 68 cable gland M20 x 1.5; 1 x blind
stopper M20 x 1.5
or:
l
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
-
Double chamber housing
l
1 x IP 68 cable gland M20 x 1.5; 1 x blind
stopper M20 x 1.5; plug M12 x 1 for VEGADIS
61 (optional)
or:
l
1 x closing cap ½ NPT, 1 x blind stopper
½ NPT, plug M12 x 1 for VEGADIS 61
(optional)
Connection cable
-
Configuration
four wires, one suspension cable, one breather
capillary, screen braiding, metal foil, mantle
-
Wire cross-section
0.5 mm² (AWG 20)
-
Wire resistance
<
0.036 Ω/m (0.011 Ω/ft)
-
Tensile strength
>
1200 N (270 pounds force)
-
Standard length
5 m (16.4 ft)
58
VEGABAR
65 • Profibus PA
10 Supplement
28253
-EN
-090522