VEGA VEGAFLEX 55K User Manual
Page 9
VEGAFLEX 55K
9
Product description
Accuracy
(under reference conditions acc. to IEC 770 - relating to the max. meas. range)
Linearity error
< 0.1 %
Temperature drift
0.015 %/10 K
Resolution of the 4 … 20 mA signal
0.025 % of range (DA converter)
Resolution
1 mm
Characteristics
Min. span between
full and empty adjustment
- analogue output signal
10 mm
Ambient conditions
Vessel pressure
-1 … 40 bar
Ambient temperature on the housing
-40°C … +60°C
Process temperature
-40°C … +150°C
Storage and transport temperature
-40°C … +80°C
Protection
IP 66/IP 67 (meets both protection standards)
Protection class
- two-wire sensor
II
- four-wire sensor
I
Overvoltage category
III
Min. dielectric constant
ε
r
> 1.5
Process fittings
VEGAFLEX 55
G
3
/
4
A,
3
/
4
" NPT, G 1A, 1" NPT, G 1
1
/
2
A, 1
1
/
2
" NPT
1.4435 (stst) or Hastelloy C22 plated
flanges
Ex technical data
Ex-Zone 0 acc. to ATEX II 1/2 G
Ex Zone 0 EEx ia IIC T 6 acc. to ATEX II 1/2 G
Ex Zone 0 EEx d ia IIC T 6 acc. to ATEX II 1/2 G
The permissible operating data of the VEGAFLEX sensors for Ex areas are listed in the
certificate.
Materials
Housing
PBT (Valox) or
Aluminium (powder-coated)
Coax rod
1.4435 (stst: 316L) or Hastelloy C22