beautypg.com

VEGA VEGAFLEX 55K User Manual

Page 10

background image

10

VEGAFLEX 55K

Product description

Connection cables

Two-wire sensor
- power supply and signal via one two-wire cable.

The cable resistance depends on the supply voltage (see diagram).

Conductor cross-section

generally 2.5 mm

2

Ground connection

max. 4 mm

2

Cable entry

2 x M20 x 1.5 (cable diameter 5 … 9 mm)

2 x

1

/

2

" NPT with ExD housing

CE conformity

VEGAFLEX sensors meet the protective regulations of EMC (89/336/EWG) and NSR
(73/23/EWG). Conformity has been judged acc. to the following standards:
EMC

Emission

EN 50 081 - 1: 1992

Susceptibility

EN 50 082 - 2: 1995

NSR

EN 61 010 - 1: 1993

Display

Display

scalable, analogue and digital display of
measured values (option).

An external measured value display, powered by the sensor, can be mounted at a distance
of up to 25 m from the sensor.

Signal output

Signal output
- two-wire technology

4 … 20 mA (see diagram)

Resolution of the 20 mA signal

0.025 % of range

Load

0 … 500

Two-wire technology:
The analogue 4 … 20 mA output signal (measuring signal) is transmitted together with the
power supply via one two-wire cable.