V-Tech IP-MR18 Manual User Manual
Page 11

Item
Description
Factory
set
Monitor Timing
To show the monitor time,Range from 6s to 600s
30s
Switch Timing
Reserve
---
Wait Timing
To show the time during which the door station keeps
calling, when door station is making a call, ranging
from 10s to 600s
30s
Talk Timing
To show time available for the conversation when door
station is talking, ranging from 10s to 600s
90s
Monitor & Speak
To enable Indoor Monitor under monitoring state can
speak to Door Station at same time. If set to 1, talk
enabled; set to 0, disabled.
[1]
Monitor & Unlock
To enable Monitors under monitoring state can open
the door at the same time.If set to 0, unlock function
is disabled; Set to 1, unlock is enable;Set to 2,unlock
is enable and close at once;Set to 3,unlock is enable
and close in 5s.
[1]
Ring Numbers
To show ring times when door station calls monitor.4
options for choice. If set to 0, ring once. If set to 1,ring
twice. If set to 2, ring three times.If set to 3,cycle ring
[1]
Name List Mode
To show the namelist display mode.If set to 0,it's the
ST-Config display mode.If set to 1,it's the Simulate
display mode
[0]
Working Mode
Reserve
---
Input Mode
To show the input type when door station makes a call [****1111]
Table 2.1(Parameters):
Note:
this section is set on ST-Config software,for more detail informations,please refer to the
ST-Config software user instructions.
-9-