beautypg.com

Veris Technologies 3150 Soil EC Mapping System - Trouble-shooting User Manual

Page 2

background image

Procedure #1: EC Surveyor Instrument Signal Testing

Perform this test daily or every 10 hours of data collection to ensure you are obtaining
reliable data, and whenever EC data is questionable. The purpose of this test is to insure
that the instrument is performing properly.

The EC Surveyor is shipped with an Instrument Test Load (Part No. 10447) that will
enable you to quickly check the instrument to ensure that it is functioning properly. To
perform this test:

1) Disconnect the signal cable from the signal terminal on the EC Surveyor.
2) Connect the test load to the signal terminal.
3) Switch on the EC Surveyor and view display.
4) The display should show:
Shallow:

(2000XA and 3100) 14 (3150) 11

Deep:

(2000XA and 3100) 21 (3150) 40

5) If the readings vary significantly (more than one whole number) contact Veris

service department.

6) Once the test is complete, remove the test load and reinstall the implement

signal cable.



Figure 1.1 Signal Test Load installed (display showing proper EC readings for 2000XA and
3100)

Signal Test Load

This manual is related to the following products: