beautypg.com

Velleman projects K7300 Assembly instructions User Manual

Page 11

background image

11

Mount a shunt over the 52 min position.



Select the battery voltage to be connected using a shunt on the 1.2V to 9.6V connection.

Select the charge current with a shunt between 15mA and 750mA. The charge
current of a battery can be determined by dividing the battery capacity by 10
(then select the closest to the charge current).

ex. : A battery with a capacity of 500mA/h should be charged with a current of

50mA, thus choose 55mA.




Push on the push button in order to start the cycle. If the battery is not yet completely discharged, then the red LED
will light up to indicate that discharging has started. Charging will automatically start afterwards for 14h.

26. FAST CHARGE (52 mins)

Fast charge (52 mins)