beautypg.com

Connection example – Velleman projects K1823 Assembly instructions User Manual

Page 6

background image

6

Connection example

9. Connection example

Execute the connection as
depicted in the figure. Connect
the alternating voltage of a
transformer with the ‘AC IN’
connections. Connect the
output voltage with the ‘+’ and
‘-‘ connections. Set the desired
output voltage with trimmer
RV1. Mount VR1 on a suitable
heatsink for applications
requiring more power.
Be sure to provide sufficient
electric insulation: fit an
insulator and a plastic
insulation ring between the
VR1 and the heatsink because
the metal side of the VR1 is
electrically connected with the
rest of the circuit.
Replace the trimmer with a
potentiometer of the same
rating if you want to use the
circuit as a permanently
adjustable power supply.


















Fig. 1.0

FUSEHOLDER

FUSE 250mA T

STRAIN RELIEF

AC POWER

ON-OFF SWITCH

TRANSFORMER

ENCLOSURE

Mica washer

TO220

isolator

DC

OUTPUT

+
-

DC output adjust

SI

LI

CO

N

GR

EA

SE