You can now activate your K8006

When you start up your K8037, LD1 & LD2 will flash together for a couple of seconds until the self-test is
completed. The indication LEDs display any irregularity the CPU may discover (read "LED indication in case of
error" below). Following the self-test, LD2 will flash once when the net frequency is 50Hz or twice for 60Hz.

The module is now operational.

Press an arbitrary button momentarily to activate or deactivate the light source or hold the button to adjust
the luminous intensity.

LED indications in case of normal operation:

LD2 (yellow LED):

Flashes once every 5 seconds when the module is in standby mode (lamp OFF).
Flashes slowly (2x/sec) when the lamp is burning, but not at full luminous intensity.
Stays ON when max. luminous intensity has been reached.
Flashes very quickly (10x/sec) while the luminous intensity is being adjusted.


LD1 (red LED):

Flashes slowly together with LD2 (yellow LED) if the luminous intensity is too low. This only happens with

JP3 in the ‘2-3’ position.