Addressing:
Enter a unique address (from ‘00’ to ‘FE’ except for 'B1', ‘C1’, ‘D1’, ‘E1’, ‘F1’ and ‘FF’) for each module through the
‘ADDR’ rotating switches. These addresses can be used to learn the push buttons.
In case of a modification of the addresses, the UP and DOWN outputs will be disabled and all LEDs of the
corresponding push buttons will be turned out.
Switch-off delay:
The complete rise or descent of the roll-down shutter (or blind) takes some time. The output of the blind control
module has to be activated during min. this period of time. To avoid surcharging the engine, the output of the
module will shut off after a period depending on the setup of the bipolar toggle switch.:
TIME OUT
switch 1
TIME OUT
switch2
Switch-off
delay
On
On
15s
Off
On
30s
On
Off
1min
Off
Off
2min
Enter a time which is just a little longer than the time needed for the shutter to rise or descend completely
Operation:
• A short press on the UP or DOWN push button will rise or descend the roll-down shutter. After the set switch-
off delay the module will switch off automatically.
• Stop the shutter at any time by pressing a push button of the opposite direction.
• Maintaining the UP or DOWN push button pressed will move the shutter until the push button is released or
the switch-off delay has expired.
• Pressing the UP and DOWN push buttons simultaneously will switch off the shutter motor.
• Pressing the IMMEDIATE UP push button will rise the shutter completely even if it was descending.
• Pressing the IMMEDIATE DOWN push button will descend the shutter completely even if it was rising.
• The up and down commands will be operated through a single push button as from firmware version 0804.
Operate this push button to move the blind, operate again to stop the blind, operate again to move the blind in
the opposite direction. Press and hold the push button and release to stop the blind motor.
LED indication:
The LEDs of the control modules and the operation LEDs on the blind control module will indicate the status:
• The power LEDs do not light up if the DOWN and UP outputs are switched off.
• The DOWN power LED blinks if the DOWN output is switched on and the switch-off delay has started.
• The DOWN power LED lights if the DOWN output is switched on and the switch-off delay is not activated.
• The UP power LED blinks if the UP output is deactivated and the switch-off delay has started.
• The UP power LED lights if the UP output is activated and the switch-off delay is not activated.