1) Standard discharge
current: 100% of nominal
capacity is obtained by
discharging the cells at
this current rates.
2) The maximum current is
determined for a yield of
70% of the nominal
capacity with a cut-off
voltage of 2.0V, at 23°C.
For currents exceeding
those given above or
pulsed current, please
contact Renata.
3) In applications where the
battery is exposed to tem-
peratures above 70°C,
please contact Renata for
consultancy.
7
6
the
swiss
power source
Electrical characteristics
Model
Nominal
Standard
Max. continuous
Operating
capacity
discharge current
discharge current
Temperature
(mAh)
(mA)
1)
(mA)
2)
(C)
3)
CR1025
30
0.05
0.40
-40/+85°
CR1216 MFR
30
0.10
1.00
-30/+70°
CR1220 MFR
40
0.10
1.00
-30/+70°
CR1225
48
0.10
1.00
-40/+85°
CR1616
50
0.10
1.00
-40/+85°
CR1620
68
0.10
1.00
-40/+85°
CR1632
125
0.20
1.50
-40/+85°
CR2016 MFR
90
0.20
3.00
-30/+70°
CR2025 MFR
165
0.30
3.00
-30/+70°
CR2032 MFR
225
0.40
3.00
-30/+70°
CR2320
150
0.20
3.00
-40/+85°
CR2325
190
0.30
3.00
-40/+85°
CR2430 MFR
300
0.50
4.00
-30/+70°
CR2430
285
0.50
4.00
-40/+85°
CR2450N
540
0.80
3.00
-40/+85°
CR2477N
950
1.00
2.50