beautypg.com

Valve port location & adjustment fig. 5, Fig. 4 – Blue Ox BX88175 User Manual

Page 9

background image

© 2002, 2006

Blue Ox Division, Automatic Equipment Mfg. Co. • One Mill Road, Industrial Park

Pender, Nebraska 68047 • Phone 402-385-3051 Fax 402-385-3360 • www.blueox.us

VALVE PORT LOCATION & ADJUSTMENT

FIG. 5

FILTER

PORT

TOP

VIEW

SIDE

VIEW

SOLENOID

VALVE

"AE" PORT

RELEASE

BRAKE PEDAL

"BE" PORT

BRAKING

PULL DOWN

Turn "clockwise" for less pedal
speed. Open "BE" all the way (counter
clockwise). Open "AE" 1/2 turn from
closed to start. Make adjustments
as needed to have pedal move down
"faster" and release "slower".

"AE"/"BE" port adjustments regulate pedal movement speed only.
NOTE: Do NOT force needle valves counter clockwise or unwarranteed
damage can break the stems.

HOSE

HOSE

HOSE

292-5958 10/07 Page 9 of 10

FIG. 4

BOX ELECTRIC, CABLE & VACUUM ATTACHMENT LOCATIONS

ELECTRIC

PLUG

VACUUM

PORT

CABLE

"DOCKED"

TO BOX

TEST BUTTON

CABLE

KEEPER

KNOCKOUT

PLUG

CABLE

DOCKING

SLOT

INSERT CABLE

BALL & PLUG

TOP VIEW

SIDE VIEW

LES

S

MO

RE

CABLE

ASSEMBLY

-Always insert cable keeper plug after moving to new attachment hole.