beautypg.com

Bosch GAS 35 L AFC Professional User Manual

Page 21

background image

English | 21

Bosch Power Tools

1 609 92A 0D1 | (23.7.13)

Container
Wipe out the container 1 from time to time with a commercial-
ly available, non-scouring cleaning agent and allow to dry.

Level Sensors (see figure J)
Clean the level sensors 35 occasionally.
– Unlock the latches 11 and remove the vacuum lid 10.
– Clean the level sensors 35 with a soft cloth.
– Reattach the vacuum lid 10 again and lock the latches 11.

Storage and Transport (see figure K)
– Wind the mains cable around the cable holder 15.
– Insert the accessories into the holders provided: Vacuum

tubes 29 in holders 17, crevice nozzle 25 in holder 18,
floor nozzle 28 in holder 19.

– Undue the elastic tie-downs of the vacuum-hose holders 5

and place the vacuum hose 21 around the vacuum cleaner
lid into the holders 5.
Reattach the elastic tie-downs.

– Mount the L-Boxx onto the retainers 9.
– To prevent back injuries, remove a full disposal bag or dust

bag, or drain vacuumed-up fluids before transporting the
vacuum cleaner.
Carry the vacuum cleaner only by the carrying handle 8.

– Store the vacuum cleaner in a dry room and secure it

against unauthorised use.

– To lock the castors 14, actuate the castor brakes 13 by

pushing down.

Correction of Malfunctions

After-sales Service and Application Service

In all correspondence and spare parts orders, please always
include the 10-digit article number given on the type plate of
the vacuum cleaner.

Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. Exploded views and information on spare parts can al-
so be found under:
www.bosch-pt.com

Bosch’s application service team will gladly answer questions
concerning our products and their accessories.

Problem

Corrective Measure

The vacuum turbine does not start.

– Check mains cable, mains plug, fuse, socket outlet and filling-

level sensors 35.

Mode selector switch 6 set to “Start/Stop automatic”.
– Set mode selector switch 6 to the “vacuum” symbol and switch

the power tool connected to the socket outlet 4 on.

Vacuum turbine switches off.

– Empty container 1.

Vacuum turbine does not restart after emptying the container. – Switch vacuum cleaner off and wait 5 seconds; switch on again

after 5 seconds.

– Clean level indicators 35 as well as the space between the level

indicators 35 with a brush.

Vacuuming power decreases.

– Remove clogs from vacuum nozzle, vacuum tubes 29, vacuum

hose 21 or flat-fold filter 24.

– Replace disposal bag 23 or dust bag.

– Engage filter cover 34 properly.

– Mount vacuum cleaner lid 10 properly and lock latches 11.

– Replace flat-fold filter 24.

Dust escapes during vacuuming

– Check proper installation of the flat-fold filter 24.

– Replace flat-fold filter 24.

The automatic shut-off (wet vacuuming) does not respond. – Clean level indicators 35 as well as the space between the level

indicators 35 with a brush.

The automatic shut-off does not function with non-conductive
liquids or foam/bubbles.
– Monitor the level continuously.

Automatic filter cleaning inoperative.

– Activate the filter cleaning (actuate the AFC button 3).

– Connect the vacuum hose 21.

The automatic filter cleaning cannot be switched off.

– Contact an authorised service agent for Bosch power tools.

The automatic filter cleaning cannot be switched off.

– Contact an authorised service agent for Bosch power tools.

OBJ_BUCH-1746-002.book Page 21 Tuesday, July 23, 2013 1:17 PM