Bosch GAS 35 L AFC Professional User Manual
Page 21
English | 21
Bosch Power Tools
1 609 92A 0D1 | (23.7.13)
Container
Wipe out the container 1 from time to time with a commercial-
ly available, non-scouring cleaning agent and allow to dry.
Level Sensors (see figure J)
Clean the level sensors 35 occasionally.
– Unlock the latches 11 and remove the vacuum lid 10.
– Clean the level sensors 35 with a soft cloth.
– Reattach the vacuum lid 10 again and lock the latches 11.
Storage and Transport (see figure K)
– Wind the mains cable around the cable holder 15.
– Insert the accessories into the holders provided: Vacuum
tubes 29 in holders 17, crevice nozzle 25 in holder 18,
floor nozzle 28 in holder 19.
– Undue the elastic tie-downs of the vacuum-hose holders 5
and place the vacuum hose 21 around the vacuum cleaner
lid into the holders 5.
Reattach the elastic tie-downs.
– Mount the L-Boxx onto the retainers 9.
– To prevent back injuries, remove a full disposal bag or dust
bag, or drain vacuumed-up fluids before transporting the
vacuum cleaner.
Carry the vacuum cleaner only by the carrying handle 8.
– Store the vacuum cleaner in a dry room and secure it
against unauthorised use.
– To lock the castors 14, actuate the castor brakes 13 by
pushing down.
Correction of Malfunctions
After-sales Service and Application Service
In all correspondence and spare parts orders, please always
include the 10-digit article number given on the type plate of
the vacuum cleaner.
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. Exploded views and information on spare parts can al-
so be found under:
www.bosch-pt.com
Bosch’s application service team will gladly answer questions
concerning our products and their accessories.
Problem
Corrective Measure
The vacuum turbine does not start.
– Check mains cable, mains plug, fuse, socket outlet and filling-
level sensors 35.
Mode selector switch 6 set to “Start/Stop automatic”.
– Set mode selector switch 6 to the “vacuum” symbol and switch
the power tool connected to the socket outlet 4 on.
Vacuum turbine switches off.
– Empty container 1.
Vacuum turbine does not restart after emptying the container. – Switch vacuum cleaner off and wait 5 seconds; switch on again
after 5 seconds.
– Clean level indicators 35 as well as the space between the level
indicators 35 with a brush.
Vacuuming power decreases.
– Remove clogs from vacuum nozzle, vacuum tubes 29, vacuum
hose 21 or flat-fold filter 24.
– Replace disposal bag 23 or dust bag.
– Engage filter cover 34 properly.
– Mount vacuum cleaner lid 10 properly and lock latches 11.
– Replace flat-fold filter 24.
Dust escapes during vacuuming
– Check proper installation of the flat-fold filter 24.
– Replace flat-fold filter 24.
The automatic shut-off (wet vacuuming) does not respond. – Clean level indicators 35 as well as the space between the level
indicators 35 with a brush.
The automatic shut-off does not function with non-conductive
liquids or foam/bubbles.
– Monitor the level continuously.
Automatic filter cleaning inoperative.
– Activate the filter cleaning (actuate the AFC button 3).
– Connect the vacuum hose 21.
The automatic filter cleaning cannot be switched off.
– Contact an authorised service agent for Bosch power tools.
The automatic filter cleaning cannot be switched off.
– Contact an authorised service agent for Bosch power tools.
OBJ_BUCH-1746-002.book Page 21 Tuesday, July 23, 2013 1:17 PM