beautypg.com

Assembly – Bosch GAS 35 L AFC Professional User Manual

Page 18

background image

18 | English

1 609 92A 0D1 | (23.7.13)

Bosch Power Tools

Technical Data

Noise Information

Measured sound values determined according to EN 60704.

Typically the A-weighted sound pressure level of the vacuum
cleaner is lower than 70 dB(A). Uncertainty K= 3 dB.
The noise level when working can exceed 80 dB(A).
Wear hearing protection!

Declaration of Conformity

We declare under our sole responsibility that the product de-
scribed under “Technical data” is in conformity with the fol-
lowing standards or standardization documents: EN 60335
and the directives 2011/65/EU, 2006/42/EC,
2004/108/EC including their amendments.

Technical file (2006/42/EC) at:
Robert Bosch GmbH, PT/ETM9,
D-70745 Leinfelden-Echterdingen

Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
25.07.2013

Assembly

Before any work on the vacuum cleaner itself, pull the

mains plug.

Mounting the Vacuum-hose Holder (see figure A)

– Slide the vacuum-hose holders 5 firmly from above into the

retainers 30 intended for this purpose, until they engage.

Mounting the Vacuum Hose (see figure B)

– Mount the vacuum hose 21 onto the hose connection

piece 2 and turn it in clockwise direction to the stop.

Note: While vacuuming, an electrostatic charge develops in
the vacuum hose and accessories caused through the friction
of the dust, which the operator could experience in the form
of static discharging (dependent on environmental influences
and physical perception).
As a general rule, Bosch recommends using an anti-static vac-
uum hose (accessory), when vacuuming fine dusts and dry
materials.

Mounting VAC Accessories (see figure C)

The vacuum hose 21 is equipped with a clip system, with
which the VAC accessories (tool sleeve 20, elbow 22) can be
connected.

Mounting the Tool Sleeve
– Mount the tool sleeve 20 onto the vacuum hose 21 until

both snap-fasteners 31 of the vacuum hose can be heard
to engage.

– To disassemble, press both snap-fasteners 31 inward and

pull the components apart.

Mounting Nozzles and Tubes
– Mount the elbow 22 onto the vacuum hose 21 until both

snap-fasteners 31 of the vacuum hose can be heard to en-
gage.

– Afterwards, mount the desired VAC accessory (floor noz-

zle, crevice nozzle, vacuum tube, etc.) firmly onto the el-
bow 22.

– To disassemble, press both snap-fasteners 31 inward and

pull the components apart.

Inserting/Removing a Disposal Bag or Dust
Bag (Dry Vacuuming) (see figures D1

D2)

For dry vacuuming, a disposal bag 23 or a dust bag (accesso-
ry) can be used. This makes the disposal of the dust easier.

Wet/dry vacuum cleaner

GAS 35 L AFC

Article number

3 601 JC3 ...

... 2..

... 270

Rated voltage

V

220 –240

110

Rated power input

W

1200

1000

Frequency

Hz

50/60

50/60

Container volume (gross)

l

35

35

Net volume (for fluids)

l

19

19

Dust bag contents

l

19

19

Max. vacuum*
– Vacuum cleaner
– Turbine

hPa
hPa

230

254

211

242

Max. flow rate*
– Vacuum cleaner
– Turbine

l/s
l/s

36

74

31

71

Max. vacuum capacity

W

1380

1150

Surface of flat-fold filter

m

2

0,615

0,615

Dust category

L

L

Weight according to
EPTA-Procedure 01/2003

kg

12,2

12,2

Protection class

/

I

/

I

Degree of protection

IP X4

IP X4

* Measured with a

Ø

35 mm and 5 m long vacuum hose

The values given are valid for nominal voltages [U] of 230 V. For lower
voltage and models for specific countries, these values can vary.

Automatic Start/Stop feature*

Rated voltage

max. power

output

min. power

output

EU

220 –240 V

2200 W

100 W

UK

110 V

750 W

100 W

UK/DK

240/230 V

1800 W

100 W

CH

230 V

1100 W

100 W

* Specification of the allowable load of the connected power tool (coun-
try-specific)

Henk Becker
Executive Vice President
Engineering

Helmut Heinzelmann
Head of Product Certification
PT/ETM9

OBJ_BUCH-1746-002.book Page 18 Tuesday, July 23, 2013 1:17 PM