13
Acu-Rite Companies Inc.
SENC 50
Mechanical Specifications
Mechanical Specifications
Digital
Analog
Resolution
0.5µm
1µm
5µm
Grating pitch
20µm
Scale medium
Light transmission reflective off of chrome coated glass
Accuracy (@ 20° C) / 1000mm
± 3µm, ± 5µm
Max. slew speed (M/s)
1
Connecting cable
Length = 5, 13, and 19 ft.
Length = 5, 13, and 19 ft.
armored or vinyl
Connector: DE-9P
Connector: DE-9P
Max. cable length (ft)
20
26
75
Repeatability
Within one resolution count
Reference pulse interval
50mm fixed or Position Trac
Measuring lengths
1” - 20”
Weight
1.1 + 0.2 lbs/ft of measuring length [64g + 5.6g/in.]
Force required to move
< 0.5 (lbs)
reading head
Operating Environment
Temperature
0° to 50° C
Relative Humidity
20% to 95% (non-condensing)
Storage Environment
Temperature
- 20° to 70° C
Humidity
20% to 95% (non-condensing)
Operating current (ma)
220
180
75
Protection (IEC 529)
IP 53 when installed as per instruction