ACU-RITE DRO 200M User Manual
Page 31
Installation
DRO 200M
24
Checking Voltage and Connecting Power
Check that the voltage available at the power source is within specification before
connecting it to the readout. If required, set the voltage selector to match the line
voltage.
1.
Remove the caution label from the input module, and
use a thin-blade screwdriver in the slot at the top of the
power-input module to open the module cover.
2.
Pull the selection block out.
3.
Remove the fuse, move the shorting bar to the
other side, install the correct fuse, and push
the block back into place.
4.
Close and snap the cover shut.
The voltage setting will show through the window in the voltage selector cover.
Connect the readout to the power source using the power cord supplied.
Opening
slot
!
CAUTION
Connecting the readout to a power source outside of the
acceptable range, or making an inappropriate setting with the
voltage selector, may damage the readout, the encoders, or
both.