Measurement Range

Temperature:

32˚F to 392˚F

0˚C to 200˚C

Temperature Range:

32º to 392ºF

Rango de Temperatura:

0º a 200ºC

WARNING:

DO NOT wipe or handle hot

thermometer with wet cloth.

DO NOT lay hot thermometer

on cold or wet surface. DO NOT

heat beyond thermometer’s

temperature capacity. DO NOT

use in oven. DO NOT wash in

dishwasher. DO NOT submerse

into water

Instructions for use:

1. Press power button to power on. Press “ºF/ºC” button to select degree

units.

2. Insert probe so tip is in the middle of thickest part of meat. Be sure tip is

not touching bone, gristle, the pan or inserted in cavity of fowl.

3. After approximately 5-10 seconds the numbers stabilize to indicate the

temperature.

4. Wash probe with hot, soapy water after use to prevent

cross-contamination.

Instrucciones de uso:

1. Oprima el botón ON/OFF. Oprima el botón “ºF/ºC” para elegir la escala de

grados.

2. Inserte la sonda de manera que la punta quede en la parte media de la sección

más gruesa de la carne. Asegúrese de que la punta no esté tocando hueso,
cartílago, el sartén y de que no esté insertada en alguna cavidad del ave.

3. Después de aproximadamente 5-10 segundos los números se estabilizan

para indicar la temperatura.

4. Lave la sonda con agua caliente y jabonosa después de cada inserción

para evitar contaminación cruzada.

To calibrate: This unit has been calibrated and should read temperature accurately. To
verify accuracy, fill a container with crushed ice and add water. Wait approximately 1
minute. Insert 2" of the probe into ice bath for 10 seconds, or until the temperature
reading stabilizes. If unit doesn’t read 32˚F/0˚C, turn adjusting screw left or right to
correct the temperature to 32˚F/0˚C.

Para calibrar: Esta unidad viene ajustada de fábrica y debe indicar temperaturas precisas.
Para revisar su precisión, llene un recipiente con hielo molido y vierta agua. Espere
aproximadamente 1 minuto. Inserte la sonda a 5 cm de profundidad en el baño de hielo
durante 10 segundos o hasta que deje de cambiar la lectura de la temperatura. Si la unidad
no lee 32ºF/0ºC, gire el tornillo de ajuste en el lado de la unidad, a la izquierda o a la
derecha, hasta llegar a la temperatura correcta de 32ºF/0ºC.

Adjusting Screw

Tornillo de ajuste

ADVERTENCIA:

NO frote o sujete el termómetro
caliente con un paño húmedo. NO
coloque el termómetro caliente
sobre superficies frías o húmedas.
NO caliente el termómetro más allá
de su capacidad de temperatura ya
que el tubo se puede romper. NO lo
use en el horno. NO lo lave en el
lavavajillas. NO sumerja en el agua.

Limited 1-Year Warranty

Register your product

on AcuRite.com

Garantía Limitada de 1 Año

Registre su producto

en AcuRite.com