beautypg.com

Care & maintenance display unit care, In-1 sensor care, Calibration calibrate temperature & humidity – AcuRite 00608 Weather Station User Manual

Page 8: Calibrate barometric pressure

background image

15

14

Care & Maintenance
Display Unit Care

Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep

away from dust, dirt and moisture. Clean ventilation ports regularly with a

gentle puff of air.

3-in-1 Sensor Care

Clean The Sensor

Clean with a soft damp cloth. Do not use caustic cleaners or abrasives.

Insect Prevention

Insects may cause obstructions and interrupt data by nesting in or on the 3-in-1

sensor. To limit this problem, spray sensor with a household insect repellent.

Consult the insect repellent instructions prior to use.

Snow & Freezing Weather

The 3-in-1 sensor will not be damaged by freezing conditions.

Clean the Wind Anemometer

Remove foreign matter from the outside of the sensor for free movement of the

wind anemometer. If needed, use a small amount of clear silicone spray

lubricant or graphite powder on the anemometer for improved movement.

Calibration
Calibrate Temperature & Humidity

The indoor / outdoor temperature and humidity readings can be calibrated on

the display unit to improve accuracy. Calibration can improve accuracy when

3-in-1 sensor placement or environmental factors impact your data accuracy.
1. Locate the “ ”, “SET”, and “ ” buttons on the back of the display unit.

Press AND HOLD all three buttons for at least 5 seconds.

2. The temperature will begin flashing, indicating it is ready to be calibrated.

3. Press the up or down arrow buttons to calibrate the data value higher or

lower from the actual reading.

4. Press the “SET” button to confirm the calibration adjustment. Note: The “ ”

icon remains illuminated next to calibrated values.

5. The next calibratable data will begin flashing, indicating it is ready to be

calibrated. Repeat Steps 1 - 4 to calibrate additional data.

Calibrate Barometric Pressure

The Weather Center default pressure mode is “AUTO”. In auto mode, the

pressure will calibrate itself over a 14 day Learning Mode. Barometric pressure

can be manually calibrated:
1. Locate the “ ”, “SET”, and “ ” buttons on the back of the display unit.

Press AND HOLD all three buttons for at least 5 seconds.

2. Press the “SET” button to cycle through data until the pressure value begins

flashing.

3. Press the “ ” or “ ” button to select “MANUAL” pressure mode.
4. Press the “SET” button to confirm.
5. Press the “ ” or “ ” buttons to calibrate the pressure value higher or

lower from the self-calibrated reading.

6. Press the “SET” button to confirm the calibration adjustment. Note: The “ ”

icon remains illuminated next to the calibrated value.