Command to the acr100i, Ccid command pipe bulk-out messages, Pc_to_rdr_iccpoweron – ACS ACR100I SIMFlash II User Manual
Page 10
![background image](/manuals/248151/10/background.png)
Document Title Here
Document Title Here
Document Title Here
ACR100I Reference Manual
Version 1.00
Page 10 of 20
www.acs.com
.hk
www.acs.com.hk
Offset
Field
Size
Value
Description
32
dwSynchProtocols
4
00000
000h
ACR100I does not support
synchronous card
36
dwMechanical
4
00000
000h
ACR100I does not support
special mechanical
characteristics
40
dwFeatures
4
00010
030h
ACR100I supports the following
features:
Automatic ICC clock
frequency change
according to parameters
Automatic baud rate
change according to
frequency and FI,DI
parameters
TPDU level exchange
with ACR100I
44
dwMaxCCIDMessageLen
gth
4
00000
10Fh
Maximum message length
accepted by ACR100I is 271
bytes
48
bClassGetResponse
1
00h
Insignificant for TPDU level
exchanges
49
bClassEnvelope
1
00h
Insignificant for TPDU level
exchanges
50
wLCDLayout
2
0000h No LCD
52
bPINSupport
1
00h
No PIN Verification
53
bMaxCCIDBusySlots
1
01h
Only 1 slot can be
simultaneously busy
7.1. Command to the ACR100I
7.1.1.
CCID Command Pipe Bulk-OUT Messages
ACR100I shall follow the CCID Bulk-OUT Messages as specified in CCID section 4. In addition, this
specification defines some extended commands for operating additional features. This section lists
the CCID Bulk-OUT Messages to be supported by ACR100I.
7.1.1.1.
PC_to_RDR_IccPowerOn
Activate the card slot and return ATR from the card
Offset
Field
Size
Value
Description
0
bMessageType
1
62h
1
dwLength
4
00000
000h
Size of extra bytes of this message
2
bSlot
1
Identifies the slot number for this
command