Adaptation to the gas in use

Other types of gas can be used by changing the burner s etting as follows:

1) Make sure that the oven is not connected to the electrical mains.
2) Open the oven door completely.
3) Extract the bottom of the oven after having removed the retaining screws (fig.

4).

4) Take off the burner by unscrewing the screw.
5) Unscrew the injector and replace it according to the injector table provided

separately. Reassemble the burner and the bottom of the oven, following the
above steps in the reverse order.

Flame adjustment (if applicable) - (fig. 5 and 6)

To adjust the flame, proceed as follows:
loosen the screw C and turn the ring nut D to position N for natural or methane gas, and
position GPL for cylinder gas, aligning the movable pointer on the ring nut with the
fixed pointer on the burner. An adjusted flame is obtained in this man ner.

Fig. 4 Fig. 5

Fig. 6

EXCESS AIR REGULAR FLAME LACK OF AIR

42