beautypg.com

Installation maintenance 14. maintenance – STIEBEL ELTRON PSH EL с 05.12.2011 User Manual

Page 30

background image

30

| PSH EL www.StiEbEL-ELtron.CoM

inStaLLation

MaintEnanCE

14. maintenance

DANGER Electrocution

Before any work on the appliance, disconnect all poles

of the appliance from the power supply.

DANGER Electrocution

Carry out all electrical connection and installation work

in accordance with relevant regulations.

If you additionally need to drain the appliance, observe chapter

"Draining the appliance".

14.1 checking the safety assembly and safety valve

f

f Check the safety assembly and safety valve regularly.

14.2 draining the appliance

DANGER Scalding

Hot water may escape during the draining process.

If the appliance needs to be drained for maintenance or to protect

the whole installation when there is a risk of frost, proceed as

follows:

f

f Close the shut-off valve in the cold water line.

f

f Drain the appliance by opening the shut-off valve at the

safety valve.

14.3 checking the protective anode

f

f Check the protective anode after the first year of use and re-

place if necessary.

f

f Afterwards determine the time intervals at which further

checks should be carried out.

14.4 descaling

f

f Remove loose scale deposits from the water heater.

f

f If necessary, descale the inner cylinder with commercially

available descaling agents.

f

f Only descale the flange after disassembly and never treat the

cylinder surface and protective anode with descaling agents.

14.5 installing the temperature limiter

26

�0

2�

07

�0

30

5

1

1 Limiter sensor

f

f Insert the limiter sensor into the sensor well as far as it will

go.