9
LED
Brightness
Decrease
Figure 7 – Controls
Rotate
Image
Power
Status
Light
LED
Brightness
Increase
Power
2. Power On: Press and Hold the power
button for 1 second.
The power status light will come ON. If
the power status light is GREEN, the mi-
cro CA-25 Inspection Camera batteries
are good. If the power status light is RED,
the batteries need to be changed. If the
LED does not turn ON, the batteries need
to be changed.
3. Pre-Form The Cable: If needed for the
area to be inspected, pre-form the cable.
Do not try to form bends with a radius of
less than 2" (50 mm) as this can damage
the cable.
4. LED Brightness Adjustment: Turn the
LEDs ON. The imager head is equipped
with four white LEDs to aid inspection.
Use the + and – buttons to turn ON and
adjust the brightness of the LEDs.
5. Inspection: Insert the imager head and
cable into the space to be inspected. Do
not use the imager head or cable for any-
thing other than an inspection device.
Do not use the imag er head and cable
to clear a path. Do not force the imager
head and cable through tight bends or
spaces. These uses can damage the unit
and the area to be inspected.
6. Image Rotation: If needed, the image
seen on the screen can be rotated in 180
degree increments by pressing the ro-
tate image button.
7. Power Off: When the inspection is com-
plete, carefully withdraw the imager and
cable from the inspection area. Press and
Hold the power button for 1 second to
turn the unit OFF. The unit will automati-
cally turn OFF 30 minutes after the last
button press or if the batteries drop too
low.
Viewing
The micro CA-25 Inspection Camera can be
connected to a television or other monitor
for remote viewing or recording through the
included RCA cable. Open the rubber cover
on the side of the screen and insert the RCA
cable into the TV-OUT jack.
Insert the other end into the Video In jack
on the television or monitor. The television
or monitor may need to be set to the proper
input to allow viewing.
Figure 8 – TV-OUT Jack
Cleaning
WARNING
Remove batteries before cleaning.
• Always clean the imager head and cable
after use with mild soap or mild detergent.
• Gently clean the LCD with a clean dry cloth.
Avoid rubbing too hard on the LCD.
• Wipe the hand held display unit down with
a clean, dry cloth.
Storage
The RIDGID micro CA-25 Inspection Cam era
must be stored in a dry secure area between
-4°F (-20°C) and 140°F (60°C).
Store the tool in a locked area out of the
reach of children and people unfamiliar with
the micro CA-25 Inspection Cam era.
Remove the batteries before any long period
of storage or shipping to avoid battery leak-
age.