beautypg.com

Troubleshooting, Related messages – 3M X75 User Manual

Page 48

background image

48

Troubleshooting

Troubleshooting

Related messages

When the unit's power is on, messages such as those shown below may be

displayed. When any such message is displayed on the screen, please respond

as described below. If the same message is displayed after the treatment, or if a

message other than the following appears, please contact your dealer or service

company.
Although these messages will be automatically disappeared around several

minutes, it will be reappeared every time the power is turned on.

Message

Description

CHANGE THE LAMP

AFTER REPLACING LAMP,

RESET THE LAMP TIMER.

The time the lamp timer has counted is approaching

2000 hours.

Preparation of a new lamp, and an early lamp change is

recommended. After you have change the lamp, please be

sure to reset the lamp timer(

39).

CHANGE THE LAMP

AFTER REPLACING LAMP,

RESET THE LAMP TIMER.

THE POWER WILL TURN OFF

AFTER ** hr.

The time the lamp timer has counted is approaching

2000 hours, so a lamp change within

**

hours is

recommended.

When lamp usage reaches 2000 hours, the power will

automatically be turned off. Please change the lamp by

referring to the section “Lamp”. After you have changed the

lamp, please be sure to reset the lamp timer(

39).

CHANGE THE LAMP

AFTER REPLACING LAMP,

RESET THE LAMP TIMER.

THE POWER WILL TURN OFF

AFTER 0 hr.

As the time the lamp timer has counted has reached

2000 hours, the power will soon be automatically

turned off.

Please immediately turn the power off, and change the lamp

by referring to the section “Lamp”. After changing the lamp,

please be sure to reset the lamp timer(

39).

NO INPUT IS DETECTED

ON ***

There is no input signal.

Please confi rm the signal input connection, and the status

of the signal source.

SYNC IS OUT OF RANGE

ON *** fH *****kHz fV *****Hz

ON *** fH *****kHz fV *****Hz

The horizontal or vertical wavelength of the inputted

signal is outside of the response parameters of this unit.

Please confi rm the specs for this unit or the signal source

specs.