beautypg.com

Section 7: troubleshooting, 1 sympton/solution table, 2 message/solution table – 3M MP8740 User Manual

Page 20: English

background image

© 3M 1999

3M

Multimedia Projector MP8740

ENGLISH

Section 7: Troubleshooting

17

Symptom

No picture and sound

Color is weak and tint is
incorrect

Picture is dark

Picture is not clear

LAMP indicator lights
red.

LAMP indicator blinks
red.

TEMP indicator lights
red.

TEMP indicator blinks
red.

Cause

• The Main power is not turned on.

• The power cord is disconnected.

• The setting of the input source is not

correct.

•RGB/Video/Audio wiring to projector is

not correct.

• RGB/Video wiring to projector is not correct.

• The brightness is set fully to dark.

• Audio wiring to projector is not correct.

• The volume is set to minimum.
• The unit is muted.

• The color and tint have been adjusted
incorrectly.

• The brightness and contrast has been

adjusted incorrectly.

• The lamp needs to be replaced.

• Projector is out of focus.

• Lamp will not ignite.

• Air filter door on bottom of case is open.

• Temperature inside projector is too hot.

• Cooling fan may be obstructed by metal

screen under foam air filter.

Solution

• Turn the MAIN POWER switch on.

• Insert the power cord into an AC socket.

• Set the correct input using the input select button

of the projector or the remote control.

• Connect the cable to correct input/output source.

• Connect the cable to correct input/output source.

• Press the MENU button and increase

BRIGHTNESS.

• Connect the cable to correct input/output source.
• Press the VOL button and increase VOLUME.
• Press the MUTE button.

• Adjust the color and tint correctly.

• Adjust the brightness and contrast correctly.

• Replace the lamp with a new one.

• Adjust the focus.

• Turn off power and let cool for 20 minutes, then restart.
• If problem persists call your dealer.

• Ensure air filter door is closed.

• Do not block the ventilation holes.
• Clean air filter

• Align metal screen.
• If fan blade is still obstructed, call service.

Sound is heard with
no picture

Power cannot be turned
on.

Picture is displayed
with no sound

7.1 Sympton/Solution Table

Error Message Displays

NO INPUT IS DETECTED

SYNC IS OUT OF RANGE

CHANGE THE LAMP

RESET THE LAMP TIMER

CHECK THE AIR FLOW

Cause

The projector is not detecting a signal.

The horizontal frequency of input signal
exceeds projector capability.

Lamp operation time is greater than 1,900
hours.

Lamp operating time is greater than 2000
hours. Safety feature shuts projector down
after 10 minutes.

Air flow to cooling fan is blocked.

Solution

Check cable connections to input device. Input device not
connected to this input mode, switch to next mode.

Switch projector to correct resolution.
See Appendix A.5

Change the projector lamp and reset the lamp operation
hours to zero.

Change the projector lamp and reset the lamp operation
hours to zero.

Clear air flow path to fan and clean air filter.

7.2 Message/Solution Table