Charger Specifications
All charging specifications are at nominal conditions: 77 °F (25 °C),
14.0 Vdc at 50 A charging, 120 Vac, 60 Hz unless otherwise specified.
Shutdowns and Restarts
DC low voltage shutdown
1.
Battery voltage drops below
10.6 ± 0.15 Vdc at heavy loads (more than
150 W) or 10.8 Vdc at light loads (less than
150 W) for more than 4 min and 10 sec
(± 30 s)
2.
Battery voltage is below 10.4 ± 0.2 Vdc for
3 seconds
DC low voltage restart
13.0 ± 0.15 Vdc
DC high voltage shutdown
16.0 ± 0.2 Vdc
DC high voltage restart
Less than 16.0 Vdc same as DC high voltage
shutdown. There is no hysteresis.
Inverter specifications (Continued)
Charger specifications
Charging method
•
Three-stage charging with battery temperature
compensation.
See Figure A-3.
•
Algorithm for generic flooded batteries only
•
No equalization mode
AC input voltage
100–130 Vac
AC input frequency
54–66 Hz
Minimum battery voltage
7 Vdc
The charger does not operate below this level
Maximum charger input
current
13.0 Aac
rms
Maximum charge rate
50 ± 5 ADC.
See Figure A-2, “Charging current versus
temperature derating curve” on page A–6
Charger efficiency
Greater than 80%
IP1012_AL.book Page 4 Tuesday, May 1, 2007 12:18 PM