If you have edited (altered) a patch and turn the 504 off without storing the patch, the patch will revert
to its old setting. To store an edited patch, use the following simple procedure.

Storing can be carried out in both Play mode and Edit mode.
After you have edited the patch, press the STORE key. If the unit is currently in Play mode, release

the key before 1 second has elapsed, otherwise the Direct Load function will be activated.

The display starts to flash. This condition is called the store

standby condition. If you wish, you can abandon the store
procedure at this point by pressing the EDIT key. If you press
the STORE key once more, the contents of the patch are
updated.

You can also change the patch number before storing, so that the

edited patch will be stored in a different number.

In this case, the original patch that was used as a starting point

for editing will not be changed.

If the tuning indicator flashes while the unit is being powered from the battery, the battery is
exhausted and should be replaced as described below.
Use only a 6LR61 9 V (alkaline) battery.
Using another kind of battery will result in shorter operation.

The 504 comes with 24 predefined patches that have been programmed at the factory. Also after
you have edited and stored your own patches, you can return to the factory default settings at any
time. This process is called "recalling". Returning all 24 patches to the original contents and
resetting the Bank Hold and Direct Load functions is called "all initialize".

The Recall mode is separate from the Play mode and Edit mode. You cannot switch directly to
Recall mode from these modes. The Recall mode can only be activated by turning the unit on in
a special way, as described below.

1. Turn the unit off by disconnecting the AC adapter or the guitar input cable.
2. Keep the STORE key depressed and turn the unit on.
3. The indication "AL" flashes on the display.
4. To perform "all initialize", press the STORE key once more in this condition. The

flashing rate increases and the initialization procedure is carried out. When it is
completed, the unit automatically enters the Play mode.

5. When wishing to recall only a particular patch, select the patch number in step 3,

using the same procedure as for normal patch selection.

6. When the desired patch has been selected, press the STORE key. The flashing rate

increases and the contents of the selected patch are recalled.

7. Recalling of individual patches can be carried out continuously. When you wish to

terminate the process, press the EDIT key. The unit then returns to the Play
mode. Turning the unit off also terminates the recall condition.

Effects:

26 effects
• TYPE

PRE AMP (for ACOUSTIC GUITAR)
ACOUSTIC SIMULATOR ( for ELECTRIC GUITAR )

• LIMITER (TYPE:PRE AMP,TYPE OFF)

EDGE (TYPE:ACOUSTIC SIMULATOR)

• BODY&TOP

• AIR

• MODULATION

• REVERB&DELAY

• De-AMP

• F.B. SUPPRESSOR

Maximum simultaneous effects:8

Banks and Patches:

6 banks X 4 patches = 24 patches (edit + store possible)

Analog/Digital Conversion:

18 bit,128 times oversampling

Digital/Analog Conversion:

16 bit, linear

Sampling Frequency:

31.25 kHz

Inputs:

HIGH input (standard monaural phone jack)

Input impedance: 470kilohms

Rated input level: Electric Guitars with single-coil pick ups

Acoustic Guitars with magnetic pick ups

LOW input (standard monaural phone jack)

Input impedance: 470kilohms

Rated input level: Electric Guitars with hum-bucking typ active type

Electric Acoustic Guitar

Output:

Combined line/headphone output(standerd stereo phone jack)

Max. output level: +6 dBm Output load impedance: 10 kilohms or more

Control Input:

For optional FP01 or FS01

Display:

2-digit,7-segment LED,tuning indicator,parameter cursor indicator

Power Requirements:

Optional

AC adapter 9 VDC,300mA (ZOOM AD-0006)
Battery: 6LR61 9V (alkaline) battery X 1

Battery life: Approx. 4h continuous operation

Dimensions:

147(W) X 157(D) X 49(H) mm

Weight:

480 g (without batteries)

* 0 dBm = 0.775 Vrms
* Design and specifications subject to change without notice.

Storing Patches

Replacing the Battery

Returning Patches to Factory Settings

Specifications

Cable

6LR61 9 V (alkaline) battery

Cover

13

14

15

16

b

4

b

4

A

1

(1) Edit the patch as desired.

(2) Press the STORE key.
(Unit enters store standby mode.)

(3) Select the patch for storing.

(4) Press the STORE key once more.
(Store process is completed.)

A

1

b

4

1. Turn the 504 upside down and

open the cover of the battery
compartment. (Push the catch to
unlock the cover, then lift it up.)

2. Remove the battery from the

compartment and disconnect the
battery cable. (Grasp the
terminal strip and do not pull at
the cable.)

3. Connect the battery cable to the

new battery, taking care to
observe correct polarity (+/-).
Then insert the battery into the
battery compartment.

4. Close the battery compartment

cover, taking care not to pinch the
cable. (Make sure that the cover
is properly locked.)

NOTE

When a patch is stored, the current
settings of the global parameters (De-
AMP, F.B.SUPPRESSOR) are also
stored. If the parameter settings were
changed and the unit is turned off
without storing the patch, the
parameters will revert to the old

settings.