TECHNICAL DATA
DIMENSIONS
Height
Width
Depth
Height to hotplate
900mm (nominal)
600mm (nominal)
600mm
(to front of
door panel)
Space for fixing at hotplate level
2mm minimum clearance
Space for fixing above hotplate level
Flush-see important note 'Location of Appliance' page 46.
Minimum space above hotplate
787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).
Weight of appliance
64.5kg.
Minimum distance from rear wall
5mm (spacer given by pressed spacer on vent panel).
CONNECTIONS
Gas
Rear left hand side of cooker at hotplate level.
Rc½ (½" B.S.P. female).
Electric
230V 50 Hz mains 3 core cable is supplied with an integral,
moulded plug fitted with a 13 amp fuse.
IGNITION
Spark generator
APCO 6MG 6892
GRILL
Natural Gas
Heat Input
3.3kW (11263 Btu/h)
Injector Marking
138
Injector Size
1.38mm
Cone Height
Not applicable as flame burns on surface of gauze
HOTPLATE
Natural Gas
R.H.F.
R.H.R.
L.H.R. L.H.F
Heat Input
1.0kW
2.0kW
2.0kW 2.8kW
(3412 Btu/h) (6824 Btu/h)
(6824 Btu/h)
(9554
Btu/h)
Injector Marking
079
104
104
130
Injector Size
0.79mm
1.04mm
1.04mm
1.30mm
Cone Length
10mm
15mm
15mm
10mm
MAIN OVEN
Electric
Heat Input
2.5 kW
SECOND OVEN
Natural Gas
Heat Input
2.4kW (8189 Btu/h)
Injector Marking
108
Flame Supervision Device
Diamond 'H' GSD 100/31
Dual Control
Sourdillon 60112/982
GENERAL
Ignition
H. T. Spark
Spark Gap
3-4mm
45