beautypg.com

Over temperature, Overload, Over temperature overload – Xantrex Technology RC/GS RC7 User Manual

Page 50

background image

Operation

38

975-0210-01-01

Over Temperature

The “Otemp/Less Load” System Status message indicates the
inverter/charger transformer and power components have
exceeded a safe operating temperature. Reduce the load on
the inverter. When the unit cools, it automatically resets and
resumes operation. If this condition occurs often, make sure
the inverter is in a cool location, has adequate ventilation, and
the cooling fan is operational.

Overload

The “Overload” System Status message appears when the load
on the inverter/charger exceeds the maximum power rating of
the unit. Reduce the load and restart the inverter/charger by
pressing the On/Off button on the RC/GS and RC7 twice.

Figure 4-13 Over-temperature Error Message

Note:

Press any arrow button to cancel the buzzer.

Figure 4-14 Overload Error Message

Inverter

Charge

Batt. Full

Error

822-4A-001

System Status:

Otemp/Less Load

!

Error LED

ON

Buzzer sounds

Error Condition

Remedy

Inverter

Charge

Batt. Full

Error

822-4A-001

System Status:

Overload

!

Error LED

ON

Buzzer sounds (press
arrow button to cancel)

Error Condition

RC-GS_manual.book Page 38 Thursday, May 26, 2005 4:58 PM