beautypg.com

Xantrex Technology RC/GS RC7 User Manual

Page 45

background image

System Status Displays

975-0210-01-01

33

The Gen Quiet Fault error is automatically reset at the end of
the quiet time period if no other action is taken.

Figure 4-5 Gen Quiet Fault Error Message

Note:

If the generator is manually started from the RC/GS, the

generator will not shut down automatically. “Man Stop Only”
(Figure 4-6) is displayed. Shut down the generator manually. See
“Generator Start/Stop (RC/GS Only)” on page 44.

Note:

The Gen Quiet Fault error is not actually a system error or

fault but rather an alert that the generator has stopped because of
quiet time and an auto-start condition still exists.

Figure 4-6 Manual Stop Only Message

Inverter

Charge

Batt. Full

Error

822-4A-001

Genset Status:

Gen Quiet Fault

!

Red Error LED lights and error message
appears in the screen

Buzzer sounds

Genset Status:

MAN STOP ONLY

RC-GS_manual.book Page 33 Thursday, May 26, 2005 4:58 PM