Battery type, Figure 3-5 battery type menu items – Xantrex Technology RC/GS RC7 User Manual
Page 26

Configuration
14
975-0210-01-01
Battery Type
To ensure the batteries are receiving the proper charge
voltage, the Battery Type must be selected for the type of
batteries used in the system: GEL Cell, Flooded Lead Acid
and AGM. The default setting is GEL Cell.
This voltage varies depending on the batteries used, as
specified below.
Table 3-1 Battery Capacity Settings
Setting
Absorption Charge Time
Auto
110 minutes (1.8 hours)
125 A-hrs
60 minutes (1 hour)
250 A-hrs
90 minutes (1.5 hours)
375 A-hrs
120 minutes (2 hours)
500 A-hrs
150 minutes (2.5 hours)
1000 A-hrs
180 minutes (3 hours)
Figure 3-4 Battery Capacity menu items
Table 3-2 Battery Type and Charge Voltage
Battery Type
Bulk VDC
Float VDC
Equalize VDC
GEL Cell
14.1
13.6
Defeated
Flooded Lead Acid
14.6
13.4
15.5
AGM
14.4
13.4
15.5
Figure 3-5 Battery Type menu items
Bat Capacity:
Auto
Bat Capacity:
125 A-hrs
Bat Capacity:
250 A-hrs
Bat Capacity:
375 A-hrs
Bat Capacity:
500 A-hrs
Bat Capacity:
1000 A-hrs
Battery Type:
GEL Cell
Battery Type:
Flooded
Battery Type:
AGM